Tips and Best Practices
This page is for the tuning phase after your first working setup.
Start small
Do not hand the entire house to PELS on day one.
- Start with a few flexible loads
- Confirm that power reporting is stable
- Watch the Overview tab during a real high-load hour
Once the behavior matches your expectations, expand the managed device set.
Priority advice
- Water heaters are often good low-priority candidates because they store heat.
- Living-room thermostats are usually high priority because comfort loss is obvious.
- Bedroom heating is often higher priority at night than during the day.
- Different modes should use different priority orders if comfort changes by time of day.
Capacity tuning advice
- Set the limit slightly below the actual grid limit if you want extra safety.
- The Getting Started default of
0.3to0.5 kWfor the safety margin is a reasonable starting point.- On the hourly period, narrow it if PELS keeps limiting devices when the home is well below the hard cap. Widen toward
1.0 kWif PELS reacts later than you want — a larger margin pushes the safe pace further below the hard cap, so PELS starts limiting sooner. - On the 15-minute period, the margin is the whole buffer: PELS never paces above the hard cap minus the margin, so limiting while you are below the cap is the design rather than a sign the margin is too wide. Size it for your slowest device. Narrowing it because PELS limits below the cap removes the only room the quarter has to absorb a device that reacts late.
- On the hourly period, narrow it if PELS keeps limiting devices when the home is well below the hard cap. Widen toward
- Use Simulation mode first if you want to see what PELS would do without touching real devices.
Price optimization advice
- Thermal loads are usually the best targets.
- Start with modest temperature adjustments, such as a 3 °C cheap-hour boost and a 3 °C expensive-hour reduction.
- Set a minimum price difference so comfort is not traded away for tiny savings.
Daily budget advice
- Treat daily budget as pacing, not as an emergency brake.
- Leave the advanced tuning values at their defaults unless you have observed a real problem you are trying to solve.
- Change one value at a time and observe a full day before making another adjustment.
Troubleshooting
| Problem | What to check |
|---|---|
| No power samples received | Make sure a Flow calls Report power usage whenever your meter updates. |
| Devices do not appear | Confirm they expose supported capabilities and device classes. |
| PELS is not controlling devices | Verify Managed by PELS is on, Power-limit control is enabled, and Simulation mode is off. |
| Expected power looks wrong | Check the device Energy settings in Homey or set a more accurate load in the device settings. |
| No price data | Confirm the configured source is correct and external Flow payloads contain full-day JSON. |
| EV charger current does not change | Check the EV control mode. For Easee, check the path you chose: Use built-in device control, or the existing current-control Flow. For other chargers, check the EV charger current (A) Flow tag and charger-app action. |
For a symptom-by-symptom guide across all of PELS, see the full Troubleshooting guide.
When to dive deeper
- Use Daily Energy Budget if you want to understand whole-day pacing.
- Use Configure an EV Charger if PELS should manage charging current.
- Use Technical Reference if you want exact planner rules.
- Use Plan States when the Overview tab wording needs interpretation.